Loudspeaking and Warning Signal System
Loudspeaking and Warning Signal System is designed for talk-back communication and signaling within range of long wall set of equipment and with mine (pit) supervisor, interlock of power train switches mounted on the entry; indication of states of technological protections, machines and mechanisms of the complex, as well as for talk-back communication along shafts.
Loudspeaking and Warning Signal System is designed for talk-back communication and signaling within range of long wall set of equipment and with mine (pit) supervisor, interlock of power train switches mounted on the entry; indication of states of technological protections, machines and mechanisms of the complex.
THE EQUIPMENT PROVIDES:
· talk-back communication along face and gate conveyers, on apparatus complex, as well as along along shafts;
· single-stroke light and acoustic alarm (“knocking on”);
· interaction with mine warning system of type STARR or AUD;
· calling supervisor and conducting talks with him;
· emergency call of supervisor;
· generating warning signals and speech messages;
· visualizing emergency modes;
· visual signaling of the operation modes of selected system elements (sensors of gate conveyer, face conveyer, gate crusher, heading crusher, shearer);
· emergency shut-down of drives, identification of drives’ shut down site (visual together with speech message);
· monitoring of the system on the surface (when modem is used).
MAIN TECHNICAL CHARACTERISTICS OF THE COMMUNICATION SYSTEM:
· devices as part of the system are connected to one out of two trunks: gate (left-hand) and face (right-hand) against controller of CUKS-5BX type;
· maximum number of devices (network nodes) in the left-hand or right-hand trunk – 40 pcs;
· maximum number of loud-speaking devices in both trunks – 50 pcs
· maximum number of devices of type CUKS 1BX/2 in one trunk – 16 pcs
· maximum number of modules of type UMP 485 connected to the trunk in device of type CUKS-1BX – 16 pcs;
· minimal supply voltage of devices (network nodes) – 12.5 V DC;
· maximum supply voltage of devices (network nodes) – 15.8 V DC;
· operating temperature range from 00 to 40 0 C;
· relative air humidity at ambient temperature + 400 – 95% maximum.
Name of parameter |
Norm |
Number of trunk lines to be connected to subscriber terminals, pcs |
2 |
Maximum number of subscriber terminals in one trunk line, pcs, at least |
32 |
Level of sound pressure along loudspeaker axis upon actuation of prestarting alarm, dB, at least |
96 |
Types of sound alarm |
prestarting; coded; speech |
Time of loud speaking communication operation after de-energizing all power units, h, minimum |
4 |
Name of parameter |
Norm |
Level and type of implosion protection: · central subscriber terminal · subscriber terminal · analog signals’ discriminator · power unit |
Exia I Exia I Exia I Exdsia I |
Make in degree of protection against humidity and dust: · central subscriber terminal · subscriber terminal · analog signals’ discriminator · power unit |
Ip54 Ip54 Ip54 Ip54
|
Overall dimensions, mm, maximum: · central subscriber terminal · subscriber terminal · analog signals’ discriminator · power unit
|
448 x 636 x 116 442 x 330 x 110 360 x 340 x 180 345 x 290 x 195 |
Mass, kg, maximum · central subscriber terminal · subscriber terminal · analog signals’ discriminator · power unit
|
16 8 6 9 |
DC supply voltage, V/current drain, mA, maximum: · central subscriber terminal · subscriber terminal · analog signals’ discriminator
|
from 12.5 to 15/220 from 12.5 to 15/90 from 12.5 to 15/70 |
Power unit: · operation range of AC supply voltage at frequency [50 +/- 1] Hz, V · stability of output voltages at variation of supply voltage in the range from 90 to 250 V and load variation, % · DC output voltage for each output, V · maximum output current of each output, A, minimum · protection of each output: - for input voltage, V - for output voltage, V - for output current, A
|
from 90 to 250
2
15.0 +/- 0.3 1.5 +/- 0.3
89.5 15.3 1.5 +/- 0.3
|